Публікація:
Coaxial aperture sensor for assessing the state of biologica objects

dc.contributor.authorPanchenko, A. Yu.
dc.contributor.authorSlipchenko, N. I.
dc.contributor.authorZaichenko, O. B.
dc.contributor.authorBondarenko, I. N.
dc.date.accessioned2018-06-08T08:05:51Z
dc.date.available2018-06-08T08:05:51Z
dc.date.issued2018
dc.description.abstractWater is the main substance that makes living organisms. The state of any bioobject is characterized by the total amount of water in it and its distribution. In biological matter, water can be in two states, in the form of free water and water, associated with its macromolecules. The distribution of free water and water associated with molecules of biological matter determines its state. Therefore, the task of rapid assessment of water distribution is topical. The water molecule has a low mass and in the free state the molecules have a high relaxation frequency, which lies in the microwave range. The dipole moment of water has a high value. Therefore, at frequencies below the relaxation frequency, water has a high value of the dielectric constant. In the bound state, its electrophysical properties of water depend on the properties of the macromolecule in which it is embedded. Therefore, microwave methods and electrodynamic measurement sensors are effective means of operative measurements. They have a high speed, simple measurement procedure, do not require special preparation of samples, they allow performing non-destructive testing. Therefore, under certain conditions, they have advantages over other methods. However, the problems of using electrodynamic methods are caused by the indirect nature of the data obtained and the rather complicated process of determining the transfer function of the microwave sensor. The report presents a scheme of the microwave sensor, in which the generatrix coincides with the coordinate surfaces. For such a scheme, you can create a rigorous analytical model. Solving the task of describing fields in the working area of such a sensor allows determining the transfer function of the sensor. The presented scheme allows a principled possibility of further development. For example, in the presence of a mathematical model of changes in the properties of a bioobject under external influence. This will allow a numerical evaluation of the sensor parameters at the theoretical preparation stage. Such an approach will significantly reduce time costs and reduce the cost of design, prototyping and experimental development of specific designs.uk_UA
dc.identifier.citationCoaxial aperture sensor for assessing the state of biologica objects / A. Y. Panchenko, N. I. Slipchenko, O. B. Zaichenko, I. N. Bondarenko // Вимірювальна та обчислювальна техніка в технологічних процесах (ВОТТП'2018) : матеріали XVIII Міжнар. наук.-практ. конф., 8 – 13 черв. 2018 р., Одеса (Затока) – Одеса : Одес. нац. акад. зв'язку ім. О. С. Попова, 2018. – С. 123–124.uk_UA
dc.identifier.urihttp://openarchive.nure.ua/handle/document/5983
dc.language.isoenuk_UA
dc.subjectapertureuk_UA
dc.subjectelectromagnetic field componentsuk_UA
dc.subjecteigenfunctionsuk_UA
dc.subjectcapacitanceuk_UA
dc.subjectcoaxial lineuk_UA
dc.subjectboundary conditionsuk_UA
dc.subjectbound wateruk_UA
dc.subjectfree wateruk_UA
dc.titleCoaxial aperture sensor for assessing the state of biologica objectsuk_UA
dspace.entity.typePublication

Файли

Оригінальний пакет
Зараз показано 1 - 1 з 1
Завантаження...
Зображення мініатюри
Назва:
р.pdf
Розмір:
340.25 KB
Формат:
Adobe Portable Document Format
Ліцензійний пакет
Зараз показано 1 - 1 з 1
Немає доступних мініатюр
Назва:
license.txt
Розмір:
9.42 KB
Формат:
Item-specific license agreed upon to submission
Опис: