dc.description.abstractThe electrogenerated chemiluminescence (ECL) application of stainless steel, a robust and cost-effective material, has been developed for the first time. The type 304 stainless steel electrode shows appealing ECL performance for luminol-H2O2 system. It enables the detection of H2O2 with a linear range from 1 to 1000 nM and a limit of detection of0.456 nM (S/N = 3). The ECL method based on type 304 stainless steel electrode is more sensitive, more cost-effective,and much simpler than other ECL methods reported before. Because the stainless steel electrode has excellent performance for H2O2 detection and H2O2 participates in many important enzymatic reactions, the applications of stainless steel electrode-based ECL for the detection of enzyme activities and enzyme substrates were further investigated using glucoseoxidase (GODx) and glucose as representative enzyme and substrate. The concentrations of glucose and the activity of GODx were directly proportional to the ECL intensities over a range of 0.1 – 1000 µM and 0.001 – 0.7 U/mL with a limit of detections of 0.076 μM and 0.00087 U/mL (S/N = 3), respectively. This method was successfully used for determining glucose in honey. Because of its remarkable performance and user-friendly features, stainless steel electrode holds great promise in various electroanalytical applications, such as biosensing, disposable sensors, and wearable sensors.uk_UA
dc.identifier.citationStainless steel electrode for sensitive luminol electrochemiluminescence detection of H2O2, glucose, and glucose oxidase activity Shimeles Addisu Kitte, Wenyue Gao, Yuriy T. Zholudov, Liming Qi, Anaclet Nsabimana, Zhongyuan Liu, and Guobao Xu Anal. Chem., Just Accepted Manuscript • DOI: 10.1021/acs.analchem.7b01939 • Publication Date (Web): 23 Aug 2017uk_UA
dc.identifier.urihttp://openarchive.nure.ua/handle/document/4067
dc.language.isoenuk_UA
dc.publisherSubscriber access provided by UNIVERSITY OF ADELAIDE LIBRARIESuk_UA
dc.subjectchemiluminescence electrogenerateduk_UA
dc.subjectH2O2 detection
dc.subjectstainless steel electrode
dc.titleStainless steel electrode for sensitive luminol electrochemiluminesceuk_UA
dc.typeArticleuk_UA
dspace.entity.typePublication

Файли

Оригінальний пакет
Зараз показано 1 - 1 з 1
Завантаження...
Зображення мініатюри
Назва:
01939.pdf
Розмір:
686.75 KB
Формат:
Adobe Portable Document Format
Опис:
основная статья
Ліцензійний пакет
Зараз показано 1 - 1 з 1
Немає доступних мініатюр
Назва:
license.txt
Розмір:
9.42 KB
Формат:
Item-specific license agreed upon to submission
Опис: