Publication: Signal flow graph and alternative gain formula for multiprobe microwave multimeter
Loading...
Files
Date
2016
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The article was shown and proved that the construction of the model in the form of signal flow graph for gain determination does not necessarily use the rule of non touching loop (the Maison rule) for defining gain from generator to sensors, and it can be successfully replaced by the matrix computation.
Description
Keywords
multiprobe microwave multimeter, signal flow graph, non touchin loop rule, gain
Citation
Miroshnyk M. A. Signal flow graph and alternative gain formula for multiprobe microwave multimeter / M. A. Miroshnyk, O. B. Zaichenko, V. M. Butenko // Інформаційно-керуючі системи на залізничному транспорті. – 2016. – №6. – С. 12–17.